Parameters

Posted in MLE Series

Max working voltage:
When the maximum operating voltage is allowed to use the maximum voltage.
Leakage Current:
The max. working voltage is the allowable max. operating voltage. Leakage current: At normal working condition of devices, the tiny current through body is only about a few μA generally. The so-called normal working condition means the device under normal operating voltage (Working Voltage), that is, when the device in the pre-breakdown situation, the impedance value is extremely large considered as an insulator, so only a tiny current flows.
Max Clamping Voltage:
the maximum clamping voltage is measured at a specific current and the specific current is often used the maximum surge current value at 10,000 times.
Capacitance value:
the measurement at 1MHz condition.

MLE Specification

  • Part Number Working Voltage Clamping
    Voltage
    Leakage
    Current
    Capacitance
    Value
    ESD
    Contact
    ESD
    Air
    Symbol DC V(max) uA(Max) pF KV KV
    SFI0201-050E330NP-LF
    SFI0201-050E100NP-LF
    SFI0201-050E050PP-LF
    SFI0201-120E2R5PP-LF
    SFI0201-120E0R8PP-LF
    5
    5
    5
    12
    12
    48
    72
    72
    130
    200
    1
    1
    1
    1
    1
    33
    10
    0.5
    2.5
    0.8
    ≧8
    ≧8
    ≧8
    ≧8
    ≧8
    ≧15
    ≧15
    ≧15
    ≧15
    ≧15
  • Part Number Working Voltage Clamping
    Voltage
    Leakage
    Current
    Capacitance
    Volume
    ESD
    Contact
    ESD
    Air
    Symbol DC V(max) uA(Max) pF KV KV
    SFI0402-050E101NP-LF
    SFI0402-050E560NP-LF
    SFI0402-050E330NP-LF
    SFI0402-050E220NP-LF
    SFI0402-050E100NP-LF
    SFI0402-050E050PP-LF
    SFI0402-120E101NP-LF
    SFI0402-120E560NP-LF
    SFI0402-120E330NP-LF
    SFI0402-120E220NP-LF
    SFI0402-120E100NP-LF
    SFI0402-120E050PP-LF
    SFI0402-240E2R5PP-LF
    SFI0402-240E3R0PP-LF
    SFI0402-240E0R8PP-LF
    5
    5
    5
    5
    5
    5
    12
    12
    12
    12
    12
    12
    24
    24
    24
    52
    52
    52
    52
    72
    72
    55
    55
    55
    55
    72
    72
    200
    200
    200
    1
    1
    1
    1
    1
    1
    1
    1
    1
    1
    1
    1
    1
    1
    1
    100
    56
    33
    22
    10
    4~9
    100
    56
    33
    22
    10
    4~9
    2~4.5
    1.6~5.4
    0.8~1.5
    ≧8
    ≧8
    ≧8
    ≧8
    ≧8
    ≧8
    ≧8
    ≧8
    ≧8
    ≧8
    ≧8
    ≧8
    ≧8
    ≧8
    ≧8
    ≧15
    ≧15
    ≧15
    ≧15
    ≧15
    ≧15
    ≧15
    ≧15
    ≧15
    ≧15
    ≧15
    ≧15
    ≧15
    ≧15
    ≧15
  • Part Number Working Voltage Clamping
    Voltage
    Leakage
    Current
    Capacitance
    Value
    ESD
    Contact
    ESD
    Air
    Symbol DC V(max) uA(Max) pF KV KV
    SFI0603-050E101NP-LF
    SFI0603-050E560NP-LF
    SFI0603-050E330NP-LF
    SFI0603-050E220NP-LF
    SFI0603-050E100NP-LF
    SFI0603-050E050PP-LF
    SFI0603-120E101NP-LF
    SFI0603-120E560NP-LF
    SFI0603-120E330NP-LF
    SFI0603-120E220NP-LF
    SFI0603-120E100NP-LF
    SFI0603-120E050PP-LF
    SFI0603-240E2R5PP-LF
    SFI0603-240E3R0PP-LF
    SFI0603-240E0R8PP-LF
    5
    5
    5
    5
    5
    5
    12
    12
    12
    12
    12
    12
    24
    24
    24
    36
    36
    34
    34
    65
    55
    55
    55
    55
    55
    60
    85
    240
    240
    200
    1
    1
    1
    1
    1
    1
    1
    1
    1
    1
    1
    1
    1
    1
    1
    100
    56
    33
    22
    10
    4~9
    100
    56
    33
    22
    10
    4~9
    2~4.5
    1.6~5.4
    0.8~1.5
    ≧8
    ≧8
    ≧8
    ≧8
    ≧8
    ≧8
    ≧8
    ≧8
    ≧8
    ≧8
    ≧8
    ≧8
    ≧8
    ≧8
    ≧8
    ≧15
    ≧15
    ≧15
    ≧15
    ≧15
    ≧15
    ≧15
    ≧15
    ≧15
    ≧15
    ≧15
    ≧15
    ≧15
    ≧15
    ≧15
  • Part Number Working Voltage Clamping
    Voltage
    Leakage
    Current
    Capacitance
    Value
    ESD
    Contact
    ESD
    Air
    Symbol DC V(max) uA(Max) pF KV KV
    SFI0805-120E560NP-LF 12 60 1 56 8 15
  • 0201
  • 0402
  • 0603
  • 0805